Using a Cytek Aurora 5 lasers, scientists at Hamad Medical Corporation, developed a 43 color panel to characterize most of the immune subsets within the peripheral immune system, including conventional T cells, unconventional T cells such as invariant natural killer T cells (iNKT), Gamma delta (γδ) T-cell subsets (TCR Vδ2, TCR Vγ9) and mucosalassociated invariant T cells (MAIT), B-cell subsets, natural killer (NK) cells, plasmacytoid dendritic cells, dendritic cell subsets, hematopoietic progenitor cells, basophils, and innate lymphoid cell (ILC) subsets (CD117, CRTH2). The panel includes surface markers to analyze activation (CD38, HLA-DR, ICOS/CD278), differentiation (CD45RA, CD27, CD28, CD57), expression of cytokine and chemokine receptors (CD25, CD127, CCR10, CCR6, CCR4, CXCR3, CXCR5, CRTH2/CD294), and co-inhibitory molecules and exhaustion (PD-1, CD223/LAG-3, TIGIT), which enables a deep characterization of PBMCs from peripheral blood. Cells were analyzed on a 5-laser Cytek Aurora and data analysis was done using FlowJo. This panel can help to make a thorough interpretation of immune system, specifically when specimen quantity is low. The panel has not been completely optimized but would rather act as a guide toward the development of a workflow for optimized multicolor immunophenotyping panel.
Learn more, read the full review